LeakDtec Series Leak Detection Alarm
LeakDtec Series Leak Detection Controllers & Alarms for reliable monitoring of double-walled tanks, sumps, containment areas and demanding industrial installations.
Available as the single-channel LD1C and four-channel LD4C, with dedicated technical specifications and capabilities for each model.
The LD4C provides four sensing inputs, four relay outputs and RS485 Modbus communication for integration with compatible PLC, SCADA and BMS systems.
Description
LeakDtec Series Leak Detection Controllers & Alarms
The LeakDtec Series provides a comprehensive leak detection control and alarm solution for double-walled tanks, containment areas, sumps and demanding industrial applications.
LeakDtec controllers operate together with compatible leak detection sensing cables and provide immediate notification when liquid is detected, enabling rapid operator response and helping reduce product loss and equipment damage.
The series includes the single-channel LD1C for localized monitoring and the four-channel LD4C for applications requiring simultaneous monitoring of up to four independent sensing cables.
The LD4C additionally provides four independent relay outputs and RS485 communication using the industrial Modbus protocol, allowing integration with compatible PLC, SCADA, BMS and automation systems.
LD1C – Single-Zone Leak Detection Controller
| Specification | LD1C |
| Type | Single-Zone Leak Detection Controller / Alarm |
| Detection Channels | 1 |
| Operating Voltage | 24 VDC |
| Maximum Current Consumption | 20 mA |
| Response Time | ≤1 sec |
| Operating Temperature | -40 to +70°C |
| Operating Humidity | 0–95% RH |
| Output | 2 A Relay |
| Housing | ABS / Polycarbonate |
| Housing Construction | Corrosion-Resistant Thermoplastic |
| Protection Class | NEMA 4X / IP67 |
| Leak Alert | Real-Time |
| Front Indicators | POWER / RUN / LEAK |
| Sensor Connection | Cable Grip Quick Connect |
| Power Connection | Cable Grip Quick Connect |
| Tool Requirement | Tool-Free Connection |
| Sensor Connectivity | Modular Compatible Sensing Cable Connection |
LD4C – Four-Zone Leak Detection Controller
| Specification | LD4C |
| Type | Four-Zone Leak Detection Controller |
| Detection Channels | 4 |
| Sensing Cable Inputs | 4 Independent Inputs |
| Power Supply | 12–24 VDC |
| Operating Current | <0.1 A |
| Operating Temperature | -20 to +75°C |
| Output Signals | 4 |
| Relay Outputs | 4 Independent Relay Outputs |
| Relay Terminals | NO / NC / NM per Output |
| Communication Interface | RS485 |
| Communication Protocol | Modbus |
| Default Communication Rate | 9600 baud |
| Selectable Communication Rates | 4800 / 9600 / 19200 baud |
| Communication Format | N, 8 |
| Power Indicator | Green POWER LED |
| Alarm Indicators | 4 Red LEDs – ALM1 / ALM2 / ALM3 / ALM4 |
| Visual Leak Alarm | Yes |
| Audible Leak Alarm | Yes |
| Alarm Silence | Alarm Silence Button |
| Maximum Sensing Cable Length | 2500 ft / approx. 800 m |
| Digital Signal Output | Yes |
| Anti-Static Protection | Yes |
| Surge Protection | Yes |
| Lightning Protection | Yes |
| RS485 Interface | RS+ / RS- |
| Power Interface | 3.5 mm DC Power Interface |
| Dimensions | 104 × 59 × 28 mm |
| Remote Monitoring | RS485 Modbus to Compatible PLC / SCADA / BMS / Automation Systems |
Note: The LD4C has a dedicated technical datasheet. Its specific 12–24 VDC power supply, <0.1 A operating current and -20 to +75°C temperature range should be used instead of the LD1C specifications.
Compatible Leak Detection Cables
| Part Number | Description |
| LDC-G-X | 2-Wire General Purpose Leak Detection Cable – PE / Cu |
| LDC-P-X | 4-Wire General Purpose Leak Detection Cable – PE / Cu |
| LDC-PC-X | 4-Wire Chemical / Corrosive Media Leak Detection Cable – PE / Cu |
IMPORTANT
LeakDtec® controllers are not the liquid sensing element by themselves. A compatible sensing cable is required for actual leak detection.
RS485 Modbus communication applies to the LD4C and should not be considered an LD1C feature.
LD1C and LD4C have different electrical and operating specifications. Model selection should therefore be based on the number of required detection zones, communication requirements and overall control-system architecture.
![]()
Dimensions
Dimensions LD1C

Dimensions LD4C