Double Controller for pH and Chlorine with WEB Control
Double Instrument for measuring and adjusting pH and Chlorine by redox or ppm. It is suitable for industrial water and waste treatment plants, pools, drinking water. Ready to operate and easy to install. On request WEB CONTROL by Ethernet.
Available Combination
pH 0÷14.00 / Redox +1.000 mV
pH 0÷14.00 / Free Chlorine 0÷20.0 ppm Cl2
Description
Double Controller for pH and Chlorine with WEB Control
Innovative double instrument for measuring and adjusting pH and Chlorine by redox or ppm Cl2. It is suitable for small and large swimming pools, industrial water treatment plants, drinking water, cooling towers, hydroponics. Ready to operate and easy to install. Compact in IP65 box for wall mounting.
This Double Controller for pH and Chlorine with WEB Control is a valid, low cost measurement and requlation system for free-chlorine. Also can be used as 0/20mA or 4/20mA visualized transmitter for field applications.
2 free-standing relay outputs, pure contact [ON-OFF, PWM, WINDOW, ALARM] and 3rd pulse proportional relay (similar
Backlit LCD display with high efficency with 2 lines of 16 digits per line, allows the conteporaneous visualization of parameters: chemical measure and temperature
On request is possible to have an output for local or WEB CONTROL by Ethernet connection.
|
Using the programming menu, it is possible to select the available measurement scale to ensure operating versatility with a single instrument.
Instrument recognizes the buffer solution and completes the calibration suspending the dosage (HOLD) and showing the electrode’s effciency in %.
Technical Data
V-MS Double | |
Available Combination: pH / Redox (ORP) pH / Free Chlorine (CL) |
0÷14.00 / +1.000 mV 0÷14.00 / 0÷20.0 ppm Cl2 |
Temperature | 0÷100 C με PT100 |
Resolution | 1% FS |
Calibration | 2 Auto/manual for Zero & Sensitive Software assisted |
Temp. Compensation | Automatic or Manual from 0 to 100 C |
Enviroment | -5 to 50 C max RM 95% |
Relay 1 Contact Type Max resistance load Hysteresis Delay Start Delay End | ON/OFF , PWM, INTERVAL Free Voltage (Dry Contact) 8A 250V AC Yes Yes Yes |
Relay 2 Contact Type Max resistance load Hysteresis Delay Start Delay End | ON/OFF , PWM, INTERVAL Free Voltage (Dry Contact) 8A 250V AC Yes Yes Yes |
Relay 3 Contact Type | Proportional Pulse similar to meter signal |
Analog Output | 0/4÷20 , 20÷4/0 mA (+/- 2%) κατ’ επιλογήν |
OFA (Over Feed Alarm) or UFA (Under) | Alarm if the value exceeds a set point |
pH/ORP/CL Security Time | Alarm if variation lower than +0.4pH / +20mV / +0.4ppm |
pH Stability | Allows to block the outputs RX or Chlorine until pH reaches the setpoint. |
Statistics | Yes |
Screen | 2 Lines 16 Characters Backlit LCD |
Keyboard | 4 buttons |
Power Supply | 90-260 VAC 50/60 Hz |
Power Consumption | 12 W |
Protection | IP 65 |
On request | Connector RJ45 and Ethernet cable to local or remote control via WEB |
On request | USB port |
Specifications can change without notice
WEB CONTROL
First Screen
Measurements Screen
Graphics Screen
Relay 1 & 2 Screen
Relay 3 Screen (pulse)
Analogic Output mA Screen
Information
Suitable Probes
CG CL3 | CP CLI & CP CLO |
Connections
Dimensions
Ask A Quote
Fill the form to get a quote or more information about the product.