Shopping cart is empty
Greek  English  
    0 item(s)
Top » Catalog » Water & WasteWater Treatment Chemicals » Closed Systems
Products 
Water & WasteWater Treatment ChemicalsProducts and Chemicals for Pools and SpasSpecial Cleaners for Industries and MarineHouse Water Filters and Reverse OsmosisIndustrial Water treatment UnitsZero Waste - Recycling Vacuum EvaporatorsIndustrial Waste Purification PlantsCompact Sewage Treatment PlantsFilter Presses & AccessoriesOil Skimmers & AccessoriesIndustrial Equipment and Pumps for ChemicalsDosing Pumps and AccessoriesSpill and Leakage Management SystemsStorage Systems for Chemicals & WasteWaterInstruments and Test Kits for Water Analysis
Please Select
New Products more
Professional Osmosis 5 Stages 800 GPD
Professional Osmosis 5 Stages 800 GPD
309.00 euro
260.00 euro

 

 

Water Treatment Chemicals
for Closed Cooling & Heating Systems from


In a closed system, water circulates in a closed cycle and is subjected to alternate cooling and heating without air contact. Heat, absorbed by the water in the closed system, is normally transferred by a water-to-water exchanger to the recirculating water of an open recirculating system, from which the heat is lost to atmosphere

Closed Recirculating Cooling applications includes :

  • Close recirculating cooling water systems (chillers)
  • Close recirculating heating water systems
  • Gas engines and Compressors
  • Power Diesel engines in stationary and locomotive service
  • Automobile cooling system
  • Air conditioning chilled water systems to transfer the refrigerant cooling to air washers


Advantages  of  Closed  Systems

Closed recirculating systems have many advantages.

  • They provide better control of temperatures in heat-producing equipment, and their small makeup water requirements greatly simplify control of potential waterside problems. Makeup water is needed only when leakage has occurred at pump packings or when water has been drained to allow system repair.
  • High-quality water can usually be used for makeup, and as a result, scale deposits are not a problem.
  • Closed systems are also less susceptible to biological fouling from slime and algae deposits than open systems.
  • Closed systems also reduce corrosion problems drastically, because the recirculating water is not continuously saturated with oxygen, as in an open system.

Main  Problems

Scale
Some closed systems, such as chilled water systems, operate at relatively low temperatures and require very little makeup water. Because no concentration of dissolved solids occurs, fairly hard makeup water may be used with little danger of scale formation. However, in diesel and gas engines, the high temperature of the jacket water significantly increases its tendency to deposit scale. Over a long period, the addition of even small amounts of hard makeup water causes a gradual buildup of scale in cylinders and cylinder heads.

Corrosion
Untreated systems can suffer serious corrosion damage from oxygen pitting, galvanic action, and crevice attack. Closed cooling systems that are shut down, oxygen can enter the water until its saturation limit is reached. When the system is returned to high-temperature operation, oxygen solubility drops and the released oxygen attacks metal surfaces. The metallurgy used in constructing modern engines, compressors, and cooling systems includes cast iron, steel, copper, copper alloys, and aluminum as well as solders. If bimetallic couples are present, galvanic corrosion may develop.

Microbiological fouling
Some times when nitrite base treatments programs used, nitrites are oxidized by microorganisms. This can lead to sever biological fouling.

 

 

 

 

 



  Solutions

The three most reliable corrosion inhibitors for closed cooling water systems are :
  • Chromate
  • molybdate and
  • nitrite materials

Generally, the chromate or molybdate types have proven to be superior treatments. For mixed metallurgy systems, the molybdate inhibitors provide the best corrosion protection.

Molybdate treatments provide effective corrosion protection and an environmentally acceptable alternative to chromate inhibitors. Molybdates are thermally stable and can provide excellent corrosion protection in both soft and hard water. Molybdate inhibitors should not be used with calcium levels greater than 500 ppm.
Nitrite- molybdate-azole blends inhibit corrosion in steel, copper, aluminum, and mixed-metallurgy systems. System pH is normally controlled between 7.0 and 9.0. Recommended treatment control limits are 200-300 ppm molybdate as MoO42¯.

Nitrite is another widely accepted nonchromate closed cooling water inhibitor. Nitrite concentrations in the range of 600-1200 ppm as NO2- will suitably inhibit iron and steel corrosion when the pH is maintained above 7.0. If aluminum is also present, the corrosion problem is intensified, and a treatment level of 10,000 ppm may be required. In all cases, the pH of the circulating water should be maintained in the alkaline range, but below 9.0 when aluminum is present.

One drawback to nitrite treatments is the fact that nitrites are oxidized by microorganisms. This can lead to low inhibitor levels and biological fouling. The feed of nonoxidizing antimicrobial may be necessary to control nitrite reversion and biological fouling.

   



Corrosion Inhibitors series CorrShield

  • Molybdate/Phosphonate Corrosion Inhibitor, Closed Systems - is a superior molybdate /phosphonate based corrosion inhibitor developed to  prevents corrosion and deposits in closed and aerated cooling water systems. It contains inhibitors for steel, copper and copper alloys in combination with dispersants.
  • Nitrite Inhibitor for Closed/Chiller - multi-functional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water
  • Corrosion Inhibitor & Antifoulant for Closed Circuits containing Aluminium - is a superior corrosion inhibitor developed for use in closed water circulating systems containing aluminium. It is based on a novel blend of organic and inorganic corrosion inhibitors, including molybdate, intended to protect steel, copper and other nonferrous metals like aluminium.
  • Copper Corrosion Inhibitor - is an innovative corrosion inhibitor for closed cooling systems. It creates an insoluble polymeric surface complex on copper and its alloys.

Combined Scale and Corrosion Inhibitors series CorrShield

  • All Organic Scale & Corrosion Inhibitor - all organic scale and corrosion inhibitor for steel, aluminium and other non ferrous metals.
  • Nitrite Inhibitor for Closed/Chilled Systems with Phosphonate - multi-functional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water .
  • Multifunctional Scale Inhibitor - multi-functional, nitrite-based chemical treatment used for the control deposits in closed cooling & heating systems.

Microbiocides series Spectrus

  • Non-oxidising Biocide -  is a non-oxidising non-foaming product ideally suited for use in cooling waters to control algae and aerobic and anaerobic bacteria over a wide pH range.
  • Biodegradable Biocide - is an advanced, biodegradable non-oxidising micro-biocide developed specifically for the control of microbiological growths in cooling water systems.

Cleaners series FerroGuest

  • Pre-Commission Cleaner - an effective NTA/HEDP based cleaner for closed cooling or heating systems, developed specifically to remove iron and scale deposits from within a closed cooling or heating system.
  • Bio-Dispersant (Oil Fouling) - is a highly effective bio-dispersant against organic fouling (oil, slime etc). Is designed to improve the performance of cooling and heating water systems, where fouling by organic slimes is reducing efficiency, by removing and dispersing the oil fouling.
 

 

 

 

 

 

 

 

 

Monitoring and Testing

Effective corrosion control monitoring is essential to ensure closed system reliability. ADTEC Chemicals provides well planned monitoring program which include the following:

  • proper sampling and monitoring at critical points in the system
  • completely representative sampling
  • use of correct test procedures
  • checking of test results against established limits
  • a plan of action to be carried out promptly when test results are not within established limits
  • a contingency plan for major upset conditions
  • a quality improvement system and assessment of results based on testing and inspections

 

WhishList 
No items
Recomments 
.....OIL SKIMMER
.....BIOCAT SPILL KIT
  Company
  Profile
  Service
  Applications
  Exhibitions-News
  Contact Us
  Wish List

Water and WasteWater Treatment Chemicals
  Cooling Towers Water Treatment
  Steam Boilers Additives
  Closed Systems Additives
  Waste Water Treatment Chemicals

Water Treatment Innovative Plants
  Cromates Total Removal ACQUAFREE Cr(VI)
  Special Water Softeners RECOFLO
  Special Water Demineralizer RECOFLO-TRIFLO
  Special Water Filters SPECTRUM MICRO MEDIA

Oil Skimmers and Accessories
  Oil Recovery Systems
  OilSkimmer Models
  Zero Waste - Recycling Vacuum Evaporators
  Vacuum Evaporators ecoDPE-HP 250-2500 l/d
  Vacuum Evaporators ecoVs-HP 1200-15000 l/d
  Vacuum Evaporators ecoVR-HP 250 - 4000 l/d
  Vacuum Evaporators ecoDPM 4 - 30 m3/day
  Multistage Evaporators VsWW 10-100 m3/day
  DRYERS for Waste up to 1000 l/day

Industrial Waste Purification Plants
  Industrial Waste with Cr6+ Chemical Treatment Plants
  Industrial Waste Water Treatment Plants
  Waste Water Treatment Plants ACQUABATCH
  Decanters
  Sludge Thinkeners

Sewage Treatment Plants Compact
  Sewage Trearment Plant for 5 - 30 E.I.
  Sewage Plant for 30 - 80 Ε.Ι.
  Sewage Treatment Plants 100+ Ε.Ι.
  Waste Water Plants for Restaurants amd Bar
  Waste Water Treatment Plants for Car Stations

Filter Presses and Accessories
  FilterPress Models
  General for FilterPresses
  Industrial Pumps for Waste and Chemicals
  Air Operated Double Diaphragm Pumps

Dosing Pumps Accessories
  Electromagnetic Dosing Pumps
  Motor Drive Metering Dosing Pumps
  Pulse Flow Meters
  Chemicals Dosage Tank with Safety Bund

Spill and Leakage Management Systems
  Spill Kits Standard
  Spill Kits Specialist
  Biocat Spill Kits
  Cork Based Oil Absorbents
  Spill Collecting Decks
  Spill Collecting Floors
  Spill Collecting Trays

Storage Systems for Chemicals & WasteWater
  Storage Systems
  Plastic Storage Tanks
  Tanks with Safety Bund
  Portable Storage Tanks
  IBC Tanks 1000 lt
  Instruments and Test Kits for water Analysis
  pH Meters
  Conductivity Meters
  Redox ORP
  Free Chlorine Meters
  Dissolved Oxygen
  Temperature Meters
  Electrodes for Panel Instruments
  Buffer Solutions

Information
  Ask A Quote for Products
 
Ask A Quote for Service
  Order - Payment - Shipping
  Privacy Notice
  Conditions of Use

Brochures
  ADTEC Chemicals
  Spill and Leakage Management System
  Electromagnetic Dosing Pumps

Our Videos